Infrared thermometers are designed for non-contact temperature taking for objects that are too hard or too dangerous to reach. Equipped with a high quality infrared sensor, this industrial thermometer is very accurate and easy and safe to operate a good distance away from the target object.
Technical Specifications of Infrared Thermometer
PART NO. | |||||
Temperature Range | -32~350℃ (-26~662ºF) |
-50~550 ℃ (-58~1022ºF) |
-50~700 ℃ (-58~1292ºF) |
-50~900 ℃ (-58~1652ºF) |
-18~1 150℃ (0~2102ºF) |
Accuracy | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ |
Repeatability | ±1% or ±1 ℃ | ±1% or ±1 ℃ | ±1% or ±1 ℃ | ±1% or ±1 ℃ | ±1% or ±1 ℃ |
Distance Spot Ratio | 12:1 | 12:1 | 12:1 | 12:1 | 50:1 |
Emissivity | 0.95 | 0.95 | 0.10~1.00 adjustable | 0.10~1.00 adjustable | 0.10~1.00 adjustable |
Resolution | 0.1 ℃ or 0.1ºF | 0.1 ℃ or 0.1 ºF | 0.1 ℃ or 0.1 ºF | 0.1 ℃ or 0.1 ºFadjustable | 0.1 ℃ or 0.1 ºF |
Response Time | 500ms | 500ms | 500ms | 500ms | 500ms |
Wavelength | 8-14µm | 8-14µm | 8-14µm | 8-14µm | 8-14µm |
℃/ ºF Selection | √ | √ | √ | √ | √ |
Data Hold Function | √ | √ | √ | √ | √ |
Laser Target Pointer On/Off Selection | √ | √ | √ | √ | √ |
Backlight On/Off Selection | √ | √ | √ | √ | √ |
Auto Power Shut Off | √ | √ | √ | √ | √ |
Power | 9V battery | 9V battery | 9V battery | 9V battery | 9V battery |
MAX/MIN/A VG/DIF reading | - | - | √ | √ | √ |
High /Low Temperature Alarm Setup | - | - | √ | √ | √ |
Data Store Recall Function | - | - | √ | √ | √ |
PART NO. | ||||
Temperature Range | -18℃~1350℃ (0~2462 ºF) | 200℃~1650℃ (390~3002 ºF) | 200℃~1850℃ (392~3362 ºF) | 200℃~2200℃ (392~3992 ºF) |
Accuracy | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ | ±1.5% or ± 1.5 ℃ |
Repeatability | ±1% or ±1 ℃ | ±1% or ±1 ℃ | ±1% or ±1 ℃ | ±1% or ±1 ℃ |
Distance Spot Ratio | 50:1 | 50:1 | 80:1 | 80:1 |
Emissivity | 0.10~1.00 adjustable | 0.10~1.00 adjustable | 0.10~1.00 adjustable | 0.10~1.00 adjustable |
Resolution | 0.1 ℃ or 0.1 ºF | 0.1 ℃ or 0.1 ºF | 0.1 ℃ or 0.1 ºF | 0.1 ℃ or 0.1 ºF |
Response Time | 500ms | 500ms | 500ms | 500ms |
Wavelength | 8-14µm | 8-14µm | 8-14µm | 900-1700µm |
℃/ ºF Selection | √ | √ | √ | √ |
Data Hold Function | √ | √ | √ | √ |
Laser Target Pointer On/Off Selection | √ | √ | √ | √ |
Backlight On/Off Selection | √ | √ | √ | √ |
Auto Power Shut Off | √ | √ | √ | √ |
Power | 9V battery | 9V battery | 9V battery | 9V battery |
MAX/MIN/A VG/DIF reading | √ | √ | √ | √ |
High/Low Temperature Alarm Setup | √ | √ | √ | √ |
Data Store Recall Function | √ | √ | √ | √ |